<?xml version="1.0"?>
<rss version="2.0"><channel><title/><link>https://metrologu.ru/blogs/blog/302-%D1%82%D0%B5%D1%85%D0%BD%D0%BE%D0%BB%D0%BE%D0%B3%D0%B8%D0%B8/</link><description/><language>ru</language><item><title>&#x414;&#x438;&#x441;&#x442;&#x430;&#x43D;&#x446;&#x438;&#x43E;&#x43D;&#x43D;&#x43E;&#x435; &#x438;&#x437;&#x43C;&#x435;&#x440;&#x435;&#x43D;&#x438;&#x435; &#x43C;&#x435;&#x442;&#x430;&#x43D;&#x430;: &#x447;&#x442;&#x43E; &#x43D;&#x43E;&#x440;&#x43C;&#x438;&#x440;&#x443;&#x435;&#x442;&#x441;&#x44F; &#x432; &#x43E;&#x43F;&#x438;&#x441;&#x430;&#x43D;&#x438;&#x438; &#x442;&#x438;&#x43F;&#x430; &#x438; &#x43A;&#x430;&#x43A; &#x43F;&#x43E;&#x432;&#x435;&#x440;&#x44F;&#x435;&#x442;&#x441;&#x44F; &#x434;&#x435;&#x442;&#x435;&#x43A;&#x442;&#x43E;&#x440; &#x43E;&#x442;&#x43A;&#x440;&#x44B;&#x442;&#x43E;&#x433;&#x43E; &#x43F;&#x443;&#x442;&#x438;</title><link>https://metrologu.ru/blogs/entry/237-%D0%B4%D0%B8%D1%81%D1%82%D0%B0%D0%BD%D1%86%D0%B8%D0%BE%D0%BD%D0%BD%D0%BE%D0%B5-%D0%B8%D0%B7%D0%BC%D0%B5%D1%80%D0%B5%D0%BD%D0%B8%D0%B5-%D0%BC%D0%B5%D1%82%D0%B0%D0%BD%D0%B0-%D1%87%D1%82%D0%BE-%D0%BD%D0%BE%D1%80%D0%BC%D0%B8%D1%80%D1%83%D0%B5%D1%82%D1%81%D1%8F-%D0%B2-%D0%BE%D0%BF%D0%B8%D1%81%D0%B0%D0%BD%D0%B8%D0%B8-%D1%82%D0%B8%D0%BF%D0%B0-%D0%B8-%D0%BA%D0%B0%D0%BA-%D0%BF%D0%BE%D0%B2%D0%B5%D1%80%D1%8F%D0%B5%D1%82%D1%81%D1%8F-%D0%B4%D0%B5%D1%82%D0%B5%D0%BA%D1%82%D0%BE%D1%80-%D0%BE%D1%82%D0%BA%D1%80%D1%8B%D1%82%D0%BE%D0%B3%D0%BE-%D0%BF%D1%83%D1%82%D0%B8/</link><description><![CDATA[<h2>
	<span>Измеряемая величина: почему не концентрация, а произведение</span>
</h2>

<p>
	<span>Детектор открытого пути освещает зону контроля узкополосным излучением на линии поглощения метана, принимает диффузно рассеянный назад сигнал и оценивает ослабление. По закону Бугера – Ламберта – Бера ослабление зависит от произведения числовой плотности молекул на длину пути в поглощающем слое. Разделить сомножители по одному измерению нельзя: протяжённость облака оператору неизвестна, отражающая поверхность возвращает луч с произвольной дистанции.</span>
</p>

<p>
	<span>Отсюда измеряемая величина – интегральная, она же столбовая концентрация. Одно и то же показание 1500 </span><span lang="EN-US">ppm</span><span>·м даст компактное плотное облако и протяжённое разреженное. Для метролога отсюда следует простое: прибор не измеряет объёмную долю в точке и не может поверяться как точечный газоанализатор подачей смеси на сенсор. Локализация утечки достигается не расчётом, а сканированием – оператор ведёт луч и смотрит, где показание растёт.</span>
</p>

<p>
	<span>Единица </span><span lang="EN-US">ppm</span><span>·м переводится в проценты НКПР·м через нижний концентрационный предел распространения пламени. Для метана НКПР принимают равным 4,4 % объёмной доли по приложению А ГОСТ Р 52136-2003; сам стандарт отменён, зарубежные справочники дают более узкий интервал воспламенения, 5–15 %. При НКПР 4,4 % один процент НКПР·м соответствует примерно 440 </span><span lang="EN-US">ppm</span><span>·м.</span>
</p>

<p align="center" style="text-align:center">
	<img class="ipsImage ipsImage_thumbnailed" data-fileid="49524" data-ratio="56.19" data-unique="xwclfa3zg" width="662" alt="image.jpeg" src="https://metrologu.ru/remoteuploads/monthly_2026_09/image.jpeg.c7d4c71a00aa5f94e9c4c1023746d33c.jpeg">
</p>

<p align="center" style="text-align:center">
	<i><span style="font-size:10.0pt">Рис. 1. Принцип действия детектора открытого пути: перестраиваемый диодный лазер, поглощение на линии метана, диффузное обратное рассеяние</span></i>
</p>

<h2>
	<span>Что именно нормировано в описании типа</span>
</h2>

<p>
	<span>Детекторы метана лазерные ГП-ПЛДМ внесены в Государственный реестр средств измерений под номером 99161-26 (приказ Росстандарта от 11.08.2026 № 1601, запись действует до 11.08.2031). Статус средства измерений имеют две модификации – ГП-ПЛДМ-15 </span><span lang="EN-US">Ex</span><span> и ГП-ПЛДМ-30 </span><span lang="EN-US">Ex</span><span>. Прочие исполнения линейки в описание типа не входят, и это первое, что сверяется при приёмке: обозначение модификации на шильде должно совпадать с записью в реестре.</span>
</p>

<p>
	<span>Нормированные характеристики модификации </span><span lang="EN-US"><a href="https://geekprom.ru/lazernye-detektory-metana/gp-pldm-30Ex-perenosnoy-lazernyy-detektor-metana/?utm_source=metrologu.ru&amp;utm_medium=article&amp;utm_campaign=pldm-metrologiya&amp;utm_content=kartochka" rel="external nofollow"><span lang="RU" style="color:#0b4f9e">ГП-ПЛДМ-30 </span><span style="color:#0b4f9e">Ex</span></a></span><span>, на документах которой разобран пример:</span>
</p>

<div align="center">
	<table border="1" cellpadding="0" cellspacing="0" style="border-collapse:collapse; border:none">
		<tbody>
			<tr>
				<td style="border:solid windowtext 1.0pt; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<b><span lang="EN-US" style="color:black; font-size:10.5pt">Характеристика</span></b>
					</p>
				</td>
				<td style="border-left:none; border:solid windowtext 1.0pt; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<b><span lang="EN-US" style="color:black; font-size:10.5pt">Значение по описанию типа</span></b>
					</p>
				</td>
			</tr>
			<tr>
				<td style="border-top:none; border:solid windowtext 1.0pt; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span style="font-size:10.5pt">Диапазон измерений интегральной концентрации метана</span>
					</p>
				</td>
				<td style="border-bottom:solid windowtext 1.0pt; border-left:none; border-right:solid windowtext 1.0pt; border-top:none; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">0–10 % НКПР·м</span>
					</p>
				</td>
			</tr>
			<tr>
				<td style="border-top:none; border:solid windowtext 1.0pt; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span style="font-size:10.5pt">Пределы допускаемой основной погрешности, поддиапазон 0–2 % НКПР·м</span>
					</p>
				</td>
				<td style="border-bottom:solid windowtext 1.0pt; border-left:none; border-right:solid windowtext 1.0pt; border-top:none; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">приведённая, ±10 %</span>
					</p>
				</td>
			</tr>
			<tr>
				<td style="border-top:none; border:solid windowtext 1.0pt; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span style="font-size:10.5pt">Пределы допускаемой основной погрешности, свыше 2 до 10 % НКПР·м</span>
					</p>
				</td>
				<td style="border-bottom:solid windowtext 1.0pt; border-left:none; border-right:solid windowtext 1.0pt; border-top:none; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">относительная, ±10 %</span>
					</p>
				</td>
			</tr>
			<tr>
				<td style="border-top:none; border:solid windowtext 1.0pt; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">Нормирующее значение приведённой погрешности</span>
					</p>
				</td>
				<td style="border-bottom:solid windowtext 1.0pt; border-left:none; border-right:solid windowtext 1.0pt; border-top:none; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">верхний предел диапазона измерений</span>
					</p>
				</td>
			</tr>
			<tr>
				<td style="border-top:none; border:solid windowtext 1.0pt; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">Дополнительная погрешность от температуры</span>
					</p>
				</td>
				<td style="border-bottom:solid windowtext 1.0pt; border-left:none; border-right:solid windowtext 1.0pt; border-top:none; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span style="font-size:10.5pt">±0,3 доли основной на каждые 10 °</span><span lang="EN-US" style="font-size:10.5pt">C</span><span style="font-size:10.5pt"> отклонения от нормальных условий</span>
					</p>
				</td>
			</tr>
			<tr>
				<td style="border-top:none; border:solid windowtext 1.0pt; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">Нормальные условия измерений</span>
					</p>
				</td>
				<td style="border-bottom:solid windowtext 1.0pt; border-left:none; border-right:solid windowtext 1.0pt; border-top:none; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">плюс 15…плюс 25 °C</span>
					</p>
				</td>
			</tr>
			<tr>
				<td style="border-top:none; border:solid windowtext 1.0pt; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">Диапазон рабочих температур</span>
					</p>
				</td>
				<td style="border-bottom:solid windowtext 1.0pt; border-left:none; border-right:solid windowtext 1.0pt; border-top:none; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">минус 20…плюс 50 °C</span>
					</p>
				</td>
			</tr>
			<tr>
				<td style="border-top:none; border:solid windowtext 1.0pt; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">Методика поверки</span>
					</p>
				</td>
				<td style="border-bottom:solid windowtext 1.0pt; border-left:none; border-right:solid windowtext 1.0pt; border-top:none; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">РТ-МП-193-205-2026</span>
					</p>
				</td>
			</tr>
			<tr>
				<td style="border-top:none; border:solid windowtext 1.0pt; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">Интервал между поверками</span>
					</p>
				</td>
				<td style="border-bottom:solid windowtext 1.0pt; border-left:none; border-right:solid windowtext 1.0pt; border-top:none; padding:0cm 5.4pt 0cm 5.4pt" valign="top" width="323">
					<p align="left" style="text-align:left">
						<span lang="EN-US" style="font-size:10.5pt">1 год</span>
					</p>
				</td>
			</tr>
		</tbody>
	</table>
</div>

<p>
	<span lang="EN-US"> </span>
</p>

<p>
	<span>Две формы нормирования в одном диапазоне – обычная для газоаналитической техники конструкция: у начала шкалы относительная погрешность росла бы неограниченно, поэтому там нормируют приведённую, а выше переходят на относительную. Нормирующим значением служит верхний предел, то есть 10 % НКПР·м; в поддиапазоне 0–2 % НКПР·м предел абсолютной погрешности получается постоянным и равным одному проценту НКПР·м.</span>
</p>

<h2>
	<span>Диапазон измерений и шкала индикации – величины разные</span>
</h2>

<p>
	<span>Руководство по эксплуатации приводит шкалу 0–100 000 </span><span lang="EN-US">ppm</span><span>·м и тут же даёт её эквиваленты: 0–227 % НКПР·м, 0–10 % объёмной доли·м. Сопоставьте с нормированным диапазоном: 0–10 % НКПР·м. Нормирована примерно двадцатая часть того, что прибор способен показать.</span>
</p>

<p>
	<span>Практический вывод для службы: показания выше 10 % НКПР·м – индикация наличия газа и порядка величины, а не результат измерения с нормированной погрешностью. В протокол и в акт такие значения переносить нельзя, их место в журнале обхода. При выборе прибора под задачу смотреть надо на верхний предел диапазона измерений, а не на предельное показание из рекламной таблицы: величины отличаются в двадцать с лишним раз.</span>
</p>

<h2>
	<span>Поверка</span>
</h2>

<p>
	<span>Для линейки утверждена методика поверки РТ-МП-193-205-2026, интервал между поверками – один год. В открытом доступе методика не размещена: перечень средств поверки, порядок операций и критерии годности берутся из неё самой, запрашивать её нужно у изготовителя или у организации, выполняющей поверку.</span>
</p>

<p>
	<span>Что стоит учесть при планировании работ. Воспроизвести интегральную концентрацию подачей смеси на сенсор невозможно – сенсора в привычном смысле здесь нет. В практике поверки приборов открытого пути эталоном служит герметичная кювета с аттестованным значением интегральной концентрации – с известным произведением объёмной доли метана на оптическую толщину; что предписано конкретно этой линейке, определяет методика. В комплект поставки такая кювета не входит, её наличие оговаривается отдельно, иначе периодическая поверка превращается в отправку прибора на сторону и простой бригады. Кому передавать прибор на поверку – вопрос отдельный: работы выполняют аккредитованные организации, в том числе </span><span lang="EN-US"><a href="https://geekprom.ru/metrologiya/?utm_source=metrologu.ru&amp;utm_medium=article&amp;utm_campaign=pldm-metrologiya&amp;utm_content=poverka" rel="external nofollow"><span lang="RU" style="color:#0b4f9e">метрологическая служба ГИКПРОМ</span></a></span><span>.</span>
</p>

<p>
	<span>Результаты поверки подтверждаются сведениями, включёнными в Федеральный информационный фонд по обеспечению единства измерений, – части 4 и 6 статьи 13 того же 102-ФЗ в редакции Федерального закона от 27.12.2019 № 496-ФЗ. Проверять действующую поверку следует по ФГИС «Аршин», а не по наклейке на корпусе: свидетельство и знак поверки оформляются дополнительно, по заявлению владельца.</span>
</p>

<h2>
	<span>Зачем прибору статус средства измерений</span>
</h2>

<p>
	<span>По статье 9 Федерального закона от 26.06.2008 № 102-ФЗ в сферах государственного регулирования обеспечения единства измерений применяются средства измерений утверждённого типа, прошедшие поверку. Производственный контроль на опасных производственных объектах в перечень таких сфер входит.</span>
</p>

<p>
	<span>Часть дистанционных течеискателей поставляется на российский рынок без утверждения типа – как индикаторы. Индикатор отвечает на вопрос «есть газ или нет», но его показание результатом измерения не является, и подкреплять им протокол, акт обследования или отчётность нельзя. Одного утверждения типа при этом тоже мало: без действующей поверки применять прибор в регулируемой сфере запрещено.</span>
</p>

<h2>
	<span lang="EN-US">Входной контроль: короткий чек-лист</span>
</h2>

<p>
	<span><span>1.<span>     </span></span></span><span>Обозначение модификации на шильде входит в описание типа – у </span><span lang="EN-US"><a href="https://geekprom.ru/lazernye-detektory-metana/?utm_source=metrologu.ru&amp;utm_medium=article&amp;utm_campaign=pldm-metrologiya&amp;utm_content=katalog" rel="external nofollow"><span lang="RU" style="color:#0b4f9e">этой линейки</span></a></span><span> статус средства измерений имеют только ГП-ПЛДМ-15 </span><span lang="EN-US">Ex</span><span> и ГП-ПЛДМ-30 </span><span lang="EN-US">Ex</span><span>; прочие исполнения в описание типа не входят.</span>
</p>

<p>
	<span><span>2.<span>     </span></span></span><span>Заводской номер и год выпуска читаются и совпадают с паспортом.</span>
</p>

<p>
	<span><span>3.<span>     </span></span></span><span>Маркировка взрывозащиты по описанию типа – 1</span><span lang="EN-US">Ex</span><span lang="EN-US"> </span><span lang="EN-US">ib</span><span lang="EN-US"> </span><span lang="EN-US">IIC</span><span lang="EN-US"> </span><span lang="EN-US">T</span><span>4 </span><span lang="EN-US">Gb</span><span lang="EN-US"> </span><span lang="EN-US">X</span><span>. Карточки и эксплуатационная документация нередко приводят её сокращённо, без уровня и без знака </span><span lang="EN-US">X</span><span>; знак </span><span lang="EN-US">X</span><span> означает особые условия применения, и эти условия надо найти в руководстве.</span>
</p>

<p>
	<span><span>4.<span>     </span></span></span><span>Сведения о поверке есть в ФГИС «Аршин», интервал – один год.</span>
</p>

<p>
	<span><span>5.<span>     </span></span></span><span>Диапазон измерений в паспорте записан в процентах НКПР·м, а не предельным показанием в </span><span lang="EN-US">ppm</span><span>·м.</span>
</p>

<p>
	<span lang="EN-US"><span>6.<span>     </span></span></span><span>Расхождения между руководством по эксплуатации и описанием типа встречаются – по ёмкости аккумулятора, времени работы, рабочему давлению, заявленной точности и времени отклика. </span><span lang="EN-US">В протоколы берутся значения описания типа: нормированы именно они.</span>
</p>

<p align="center" style="text-align:center">
	<img class="ipsImage ipsImage_thumbnailed" data-fileid="49525" data-ratio="56.19" data-unique="6a7tlyjt1" width="662" alt="image.jpeg" src="https://metrologu.ru/remoteuploads/monthly_2026_09/image.jpeg.93b9791ce6c8a6bb3c5468dfe480175f.jpeg">
</p>

<p align="center" style="text-align:center">
	<i><span style="font-size:10.0pt">Рис. 2. Маркировка прибора: взрывозащита 1</span></i><i><span lang="EN-US" style="font-size:10.0pt">Ex</span></i><i><span lang="EN-US" style="font-size:10.0pt"> </span></i><i><span lang="EN-US" style="font-size:10.0pt">ib</span></i><i><span lang="EN-US" style="font-size:10.0pt"> </span></i><i><span lang="EN-US" style="font-size:10.0pt">IIC</span></i><i><span lang="EN-US" style="font-size:10.0pt"> </span></i><i><span lang="EN-US" style="font-size:10.0pt">T</span></i><i><span style="font-size:10.0pt">4 </span></i><i><span lang="EN-US" style="font-size:10.0pt">Gb</span></i><i><span lang="EN-US" style="font-size:10.0pt"> </span></i><i><span lang="EN-US" style="font-size:10.0pt">X</span></i><i><span style="font-size:10.0pt">, </span></i><i><span lang="EN-US" style="font-size:10.0pt">IP</span></i><i><span style="font-size:10.0pt">65 и знак утверждённого типа средства измерений</span></i>
</p>

<h2>
	<span>Частые вопросы</span>
</h2>

<p>
	<b><span>Можно ли поверить детектор открытого пути на обычной поверочной установке для газоанализаторов?</span></b>
</p>

<p>
	<span>Нет. Установка воспроизводит объёмную долю в потоке, а прибор измеряет произведение концентрации на длину пути. Нужен эталон интегральной концентрации – кювета с аттестованной оптической толщиной.</span>
</p>

<p>
	<b><span>Как пересчитать </span><span lang="EN-US">ppm</span></b><b><span>·м в проценты НКПР·м?</span></b>
</p>

<p>
	<span>Через НКПР метана: при 4,4 % объёмной доли один процент НКПР·м равен примерно 440 </span><span lang="EN-US">ppm</span><span>·м, а верхний предел 10 % НКПР·м – примерно 4400 </span><span lang="EN-US">ppm</span><span>·м.</span>
</p>

<p>
	<b><span>Влияет ли на результат угол падения луча на поверхность?</span></b>
</p>

<p>
	<span>Да. Наибольшая точность достигается при отражении, близком к нормали; наклонное падение и слабо отражающая поверхность снижают уровень принимаемого сигнала, о чём прибор сообщает отдельной подсказкой.</span>
</p>

<p>
	<span>Материал подготовлен специалистами компании ГИКПРОМ (ООО «ГП»), Москва.</span>
</p>